    Hi EMTP team

    first thanks for your great software

    I found a mismatching between description of “Esm (kJ/MVA)” in MMC block and what really is in EMTP.

    description is: Capacitor energy in each Submodule (SM) per MVA

    but when check script file of MMC, you will find that  it is the sum of the all sub-modules capacitor energy of MMC per MVA

    maybe it seems less important but it will confuse the user.